Prerequisites
Before you perform this procedure:
Procedure
-
Remove the front bezel.
-
Power down the server.
-
Remove all power:
- Disconnect each power cord from the power source.
- Disconnect each power cord from the
server.
-
Disconnect all peripheral cables from the server.
-
Do one of the following:
-
Remove the access panel.
-
Remove the air baffle.
-
Remove the PCI blank retainer.
-
Remove the PCI slot blank.
-
If the M.2 SSD enablement board option does not include a screw for installation,
remove one of the preinstalled PCI board screw.
-
If the SSD is not preinstalled on the M.2 SSD enablement board, do the following:
If only one SSD is being installed, install the SSD in slot 1.
- Insert the SSD into the M.2 slot at a 45° angle.
- Carefully press the SSD down to the horizontal position.
- Install the SSD mounting screw.
- If you are installing a second SSD, repeat steps a–c.
-
Install the M.2 SSD enablement board.
-
Make sure that the board is firmly seated in the slot.
-
Install the PCI blank retainer.
-
Observe the guidelines for managing cables.
-
Connect the M.2 SATA cables.
-
Install the air baffle.
-
Install the access panel.
-
Do one of the following:
-
Connect all peripheral cables to the server.
-
Connect each power cord to the server.
-
Connect each power cord to the power source.
-
Power up the server.
-
Install the front bezel.