Installing the 4 LFF hot-plug drive cage

Prerequisites

Before you perform this procedure, make sure that you have the following items available:

Procedure
  1. Remove the front bezel.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Disconnect all peripheral cables from the server.
  5. Do one of the following:
  6. Remove the access panel.
  7. Remove the air baffle.
  8. If installed, remove the fan cage.
  9. Do one of the following:
    • If the drive cage is to be installed in box 1, remove the media bay blanks.

      Retain the blanks for future use.


    Removing the box 1 media bay blanks
    • If the drive cage is to be installed in box 2 or 3, remove the drive cage blank.

      Retain the blank for future use.


    Removing the box 2 or box 3 drive cage blank
  10. Install the drive cage.

    Installing the 4 LFF hot-plug drive cage
  11. Observe the guidelines for managing cables.
  12. Connect the drive cables:
  13. If the fan cage was removed, do the following:
    1. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs. This is done to prevent system damage due to cables being inadvertently caught under the fan cage.
    2. Install the fan cage.
  14. Install the air baffle.
  15. Install the access panel.
  16. Do one of the following:
  17. Connect all peripheral cables to the server.
  18. Connect each power cord to the server.
  19. Connect each power cord to the power source.
  20. Power up the server.
  21. Install the LFF hot-plug drives.
  22. Install the front bezel.

The installation is complete.