NVMe SSD components
Item | Description | Status |
---|---|---|
1 | Locate LED |
Solid blue = The drive is being identified by a host application. Flashing blue = The drive carrier firmware is being updated or requires an update. |
2 | Activity ring LED |
Rotating green = Drive activity Off = No drive activity |
3 | Drive status LED |
Solid green = The drive is a member of one or more logical drives. Flashing green = The drive is rebuilding or performing a RAID migration, stripe size migration, capacity expansion, or logical drive extension, or is erasing. Flashing amber/green = The drive is a member of one or more logical drives and predicts the drive will fail. Flashing amber = The drive is not configured and predicts the drive will fail. Solid amber = The drive has failed. Off = The drive is not configured by a RAID controller. |
4 | Do Not Remove LED |
Solid white = Do not remove the drive. Drive must be ejected from the PCIe bus prior to removal. Flashing white = Ejection request pending Off = Drive has been ejected |
5 | Power LED |
Solid green = Do not remove the drive. Drive must be ejected from the PCIe bus prior to removal. Flashing green = Ejection request pending Off = Drive has been ejected |
6 | Power button |
Press to request PCIe ejection. Removal request can be denied by the:
|
7 | Do not remove button | Press to open the release lever. |