Mapping drive bays
For detailed information and examples on drive bay mapping configuration changes in the HPE Apollo r2800 Chassis, see the HPE iLO 4 Scripting and Command Line Guide on the Hewlett Packard Enterprise website.
To map drives in the HPE Apollo r2800 Chassis:
Determine which drive bays to map to each node.
Using Integrated Lights Out (iLO) administrator login credentials, use a script that includes the READ_BACKPLANE_INFO command to get the current mapping information from the HPE Apollo r2800 Chassis.
Build an XML script to map the drive bays.
Using a script that includes the READ_ZONE_TABLE command, verify the changes to the zone table. The drives can also be labeled to clearly show the drive bay mapping configuration.
- Power down the nodes.
IMPORTANT: All nodes must remain powered off for at least 5 seconds after executing the configuration changes.