Checking the battery backup charge level

Procedure
  1. Using a ball tip pen, press and release the battery check button.

    After releasing the button, you might have to wait up to seven seconds before the LED starts flashing.

  2. Note the number of LED flashes and reference the following table.
    Flashes Battery State RSOC1
    0 Battery bad/failed
    1 RSOC <= 29%
    2 30% <= RSOC <= 62%
    3 63% <= RSOC <= 94%
    4 95% <= RSOC
    1

    Relative State of Charge

    The battery will fully charge within one hour of being installed into the server.