Event Identifiers 1061-1098

NT Event ID: 1061 (Hex)0xc4350425 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Physical Drive Threshold Exceeded.

Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has exceeded a drive threshold.

SNMP Trap: cpqDa5PhyDrvThreshPassedTrap - 3030 in CPQIDA.MIB

Symptom: Physical Drive Threshold Passed. This trap indicates that the agent has detected a factory threshold associated with one of the physical drive objects on a drive array, has been exceeded.

User Action: Replace the physical drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaPhyDrvCntlrIndex
  • cpqDaPhyDrvBusNumber
  • cpqDaPhyDrvBay
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum

Supporting SNMP Trap Description: “Factory threshold passed for a physical drive.”

NT Event ID: 1062 (Hex)0xc4350426 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Logical Drive Status Change.

Log Message: Logical drive number %5 on the array controller in slot %4 has a new status of %2.

SNMP Trap: cpqDa3LogDrvStatusChange - 3008 in CPQIDA.MIB

Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaLogDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqDaLogDrvStatus].”

NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Spare Drive Status Change.

Log Message: The spare drive in slot %4, port %5, bay %6 has a new status of %2.

SNMP Trap: cpqDa4SpareStatusChange - 3017 in CPQIDA.MIB

Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.

User Action: If the spare drive status is failed, replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaSpareStatus
  • cpqDaSpareCntlrIndex
  • cpqDaSpareBusNumber
  • cpqDaSpareBay

Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”

NT Event ID: 1064 (Hex)0xc4350428 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Physical Drive Status Change.

Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has a new status of %2.

SNMP Trap: cpqDa5PhyDrvStatusChange - 3029 in CPQIDA.MIB

Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status.

User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaPhyDrvStatus
  • cpqDaPhyDrvCntlrIndex
  • cpqDaPhyDrvBusNumber
  • cpqDaPhyDrvBay
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum
  • cpqDaPhyDrvFailureCode

Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”

NT Event ID: 1065 (Hex)0xc4350429 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Accelerator Status Change.

Log Message: The array accelerator board attached to the array controller in slot %4 has a new status of %2.

SNMP Trap: cpqDa5AccelStatusChange - 3025 in CPQIDA.MIB

Symptom: Accelerator Board Status Change. This trap indicates that the agent has detected a change in the status of an array accelerator cache board. The current status is represented by the variable cpqDaAccelStatus.

User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrSlot
  • cpqDaCntlrModel
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory
  • cpqDaAccelStatus
  • cpqDaAccelErrCode

Supporting SNMP Trap Description: “Status is now [cpqDaAccelStatus].”

NT Event ID: 1066 (Hex)0xc435042a (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Accelerator Bad Data.

Log Message: The array accelerator board attached to the array controller in slot %4 is reporting that it contains bad cached data.

SNMP Trap: cpqDa5AccelBadDataTrap - 3026 in CPQIDA.MIB

Symptom: Accelerator Board Bad Data. This trap indicates that the agent has detected an array accelerator cache board that has lost battery power. If data was being stored in the accelerator cache memory when the server lost power, that data has been lost.

User Action: Verify that no data has been lost.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrSlot
  • cpqDaCntlrModel
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”

NT Event ID: 1067 (Hex)0xc435042b (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Drive Array Accelerator Battery Failed.

Log Message: The array accelerator board attached to the array controller in slot %4 is reporting a battery failure.

SNMP Trap: cpqDa5AccelBatteryFailed - 3027 in CPQIDA.MIB

Symptom: Accelerator Board Battery Failed. This trap indicates that the agent has detected a battery failure associated with the array accelerator cache board.

User Action: Replace the Accelerator Cache Board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrSlot
  • cpqDaCntlrModel
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Battery status is failed.”

NT Event ID: 1068 (Hex)0xc435042c (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: SCSI Controller Status Change.

Log Message: The SCSI controller in slot %4, SCSI bus %5 has a new status of %2.

SNMP Trap: cpqScsi3CntlrStatusChange - 5005 in CPQSCSI.MIB

Symptom: SCSI Controller Status Change. The Insight Agent has detected a change in the controller status of a SCSI Controller. The variable cpqScsiCntlrStatus indicates the current controller status.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqScsiCntlrStatus

Supporting SNMP Trap Description: “Status is now [cpqScsiCntlrStatus].”

NT Event ID: 1069 (Hex)0xc435042d (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: SCSI Logical Drive Status Change.

Log Message: The SCSI logical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4, SCSI has a new status of %2.

SNMP Trap: cpqScsi3LogDrvStatusChange - 5021 in CPQSCSI.MIB

Symptom: Logical Drive Statues Change. The Storage Agent has detected a change in the status of a SCSI logical drive. The current logical drive status is indicated in the cpqScsiLogDrvStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqScsiLogDrvStatus
  • cpqScsiLogDrvCntlrIndex
  • cpqScsiLogDrvBusIndex
  • cpqScsiLogDrvIndex
  • cpqScsiLogDrvOsName

Supporting SNMP Trap Description: “Status is now [cpqScsiLogDrvStatus].”

NT Event ID: 1070 (Hex)0xc435042e (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: SCSI Physical Drive Status Change.

Log Message: The SCSI physical drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.

SNMP Trap: cpqScsi5PhyDrvStatusChange - 5020 in CPQSCSI.MIB

Symptom: Physical Drive Status Change. The Storage Agent has detected a change in the status of a SCSI physical drive. The current physical drive status is indicated in the cpqScsiPhyDrvStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqScsiPhyDrvStatus
  • cpqScsiPhyDrvCntlrIndex
  • cpqScsiPhyDrvBusIndex
  • cpqScsiPhyDrvIndex
  • cpqScsiPhyDrvVendor
  • cpqScsiPhyDrvModel
  • cpqScsiPhyDrvFWRev
  • cpqScsiPhyDrvSerialNum
  • cpqScsiPhyDrvOsName

Supporting SNMP Trap Description: “Status is now [cpqScsiPhyDrvStatus].”

NT Event ID: 1075 (Hex)0x84350433 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fan Status Change.

Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.

SNMP Trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.MIB

Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

User Action: If the fan status is degraded or failed, replace any failed fans.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxFanStatus

Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].”

NT Event ID: 1076 (Hex)0xc4350434 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: Storage System Temperature Failure.

Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a failed temperature status. Shut down the storage system as soon as possible.

SNMP Trap: cpqSs3TempFailed - 8009 in CPQSTSYS.MIB

Symptom: Storage System temperature failure. The agent has detected that a temperature status has been set to failed. The storage system is shut down.

User Action: Shut down the storage system as soon as possible. Insure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxTempStatus

Supporting SNMP Trap Description: “Storage System will be shut down.”

NT Event ID: 1077 (Hex)0x84350435 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Temperature Degraded.

Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal operating range.

SNMP Trap: cpqSs3TempDegraded - 8010 in CPQSTSYS.MIB

Symptom: Storage System temperature degraded. The agent has detected a temperature status that has been set to degraded. The storage system's temperature is outside of the normal operating range.

User Action: Shut down the storage system as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxTempStatus

Supporting SNMP Trap Description: “Temp is outside of normal range.”

NT Event ID: 1078 (Hex)0x44350436 (cpqstmsg.dll)

Log Severity: Information (1)

Event Title: Storage System Temperature OK.

Log Message: The temperature in the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has returned to the normal operating range.

SNMP Trap: cpqSs3TempOk - 8011 in CPQSTSYS.MIB

Symptom: Storage System temperature OK. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It may be reactivated by the administrator.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxTempStatus

Supporting SNMP Trap Description: “Storage System temperature ok.”

Event identifier: cpqstmsg.dll - 1098 (Hex)0x4435044a (Service Event)

Log Severity: Information (1)

Log Message: Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4, port %5, bay %6 with serial number “%7”, does not have drive threshold monitoring enabled.