Message identifiers 24625-24649
Message Id: 24625
Severity: Informational
Log message: Fan number <fan number> is reporting that it is now operational. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24626
Severity: Informational
Log message: Fan number <fan number> located on fan module <fan module number> is reporting that it is now operational. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24627
Severity: Informational
Log message: Array controller <controller name / slot information> is reporting excessive correctable PCI-e errors. Please check this controller to ensure it is functioning properly.
Message Id: 24628
Severity: Informational
Log message: Fan module <fan module number> in box <box number> was <inserted / removed>. Box <box number> is attached to port <port number> of array controller <controller name / slot information>.
Message Id: 24629
Severity: Error
Log message: Fan module <fan module number> in box number <box number> is reporting a failure. Box number <box number> is connected to port <port number> of array controller <controller name / slot information>. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drive(s).
Message Id: 24630
Severity: Informational
Log message: A tape drive connected to port <port number> of array controller <controller name / slot information> has been <inserted / removed>.
Message Id: 24631
Severity: Informational
Log message: Fan module <fan module number> in box number <box number> is reporting a degraded condition. Box number <box number> is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24632
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that its cache has been disabled.
Message Id: 24633
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that its cache has been enabled.
Message Id: 24634
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that its cache batteries are missing.
Message Id: 24635
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that its cache batteries have failed.
Message Id: 24636
Severity: Informational
Log message: Fan module <fan module number> is reporting that it is now operational. This fan module is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24637
Severity: Informational
Log message: A previously failed storage enclosure processor (SEP) is now responding and operational. This SEP is located in box <box number> which is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24638
Severity: Error
Log message: A storage enclosure processor (SEP) has failed. This SEP is located in box <box number> which is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24639
Severity: Error
Log message: All of the storage enclosure processors (SEPs) in box <box number> have failed and there is currently no environmental management and monitoring available for this storage box. Box <box number> is connected to port <port number> of array controller <controller name / slot information>.
Message Id: 24640
Severity: Informational
Log message: The Smart Array controller <controller name / slot information> is now redundant.
Message Id: 24641
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is reporting that no redundant array controller is installed.
Message Id: 24642
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not redundant because it is a different model than its partner controller.
Message Id: 24643
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is not redundant because an inter-controller link could not be established with the partner controller.
Message Id: 24644
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not redundant because it is of a different firmware revision than its partner controller.
Message Id: 24645
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not redundant because it is using a different cache size than its partner controller.
Message Id: 24646
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not redundant because its partner controller has reported a cache failure.
Message Id: 24647
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no longer redundant because this controller and its partner controller can no longer see all the physical drives.
Message Id: 24648
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no longer redundant because one or more drives has been determined not to be able to support redundant controller operations.
Message Id: 24649
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is no longer redundant because an expand operation is in progress. The controller will become redundant once again once the expand operation has completed.