Message identifiers 24625-24649

Message Id: 24625

Severity: Informational

Log message: Fan number <fan number> is reporting that it is now operational. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24626

Severity: Informational

Log message: Fan number <fan number> located on fan module <fan module number> is reporting that it is now operational. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24627

Severity: Informational

Log message: Array controller <controller name / slot information> is reporting excessive correctable PCI-e errors. Please check this controller to ensure it is functioning properly.

Message Id: 24628

Severity: Informational

Log message: Fan module <fan module number> in box <box number> was <inserted / removed>. Box <box number> is attached to port <port number> of array controller <controller name / slot information>.

Message Id: 24629

Severity: Error

Log message: Fan module <fan module number> in box number <box number> is reporting a failure. Box number <box number> is connected to port <port number> of array controller <controller name / slot information>. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drive(s).

Message Id: 24630

Severity: Informational

Log message: A tape drive connected to port <port number> of array controller <controller name / slot information> has been <inserted / removed>.

Message Id: 24631

Severity: Informational

Log message: Fan module <fan module number> in box number <box number> is reporting a degraded condition. Box number <box number> is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24632

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that its cache has been disabled.

Message Id: 24633

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that its cache has been enabled.

Message Id: 24634

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that its cache batteries are missing.

Message Id: 24635

Severity: Warning

Log message: Array controller <controller name / slot information> has reported that its cache batteries have failed.

Message Id: 24636

Severity: Informational

Log message: Fan module <fan module number> is reporting that it is now operational. This fan module is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24637

Severity: Informational

Log message: A previously failed storage enclosure processor (SEP) is now responding and operational. This SEP is located in box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24638

Severity: Error

Log message: A storage enclosure processor (SEP) has failed. This SEP is located in box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24639

Severity: Error

Log message: All of the storage enclosure processors (SEPs) in box <box number> have failed and there is currently no environmental management and monitoring available for this storage box. Box <box number> is connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24640

Severity: Informational

Log message: The Smart Array controller <controller name / slot information> is now redundant.

Message Id: 24641

Severity: Warning

Log message: The Smart Array controller <controller name / slot information> is reporting that no redundant array controller is installed.

Message Id: 24642

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is not redundant because it is a different model than its partner controller.

Message Id: 24643

Severity: Warning

Log message: The Smart Array controller <controller name / slot information> is not redundant because an inter-controller link could not be established with the partner controller.

Message Id: 24644

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is not redundant because it is of a different firmware revision than its partner controller.

Message Id: 24645

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is not redundant because it is using a different cache size than its partner controller.

Message Id: 24646

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is not redundant because its partner controller has reported a cache failure.

Message Id: 24647

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is no longer redundant because this controller and its partner controller can no longer see all the physical drives.

Message Id: 24648

Severity: Error

Log message: The Smart Array controller <controller name / slot information> is no longer redundant because one or more drives has been determined not to be able to support redundant controller operations.

Message Id: 24649

Severity: Warning

Log message: The Smart Array controller <controller name / slot information> is no longer redundant because an expand operation is in progress. The controller will become redundant once again once the expand operation has completed.