Message identifiers 24750-24774
Message Id: 24750
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between port <port number> and the switch expander connected to this port. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24751
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between a switch expander and I/O module <module number> of box <box number>. This hardware is connected to port <port number> of the external array controller. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24752
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that storage box number <box number> was added to port <port number>. This connection is through I/O module number <module number> on the storage box.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24753
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that storage box number <box number> was removed from port <port number>. This connection was through I/O module number <module number> on the storage box. This event can occur when either a sole I/O module or data cable is removed.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24754
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that either redundant I/O module number <module number> in box <box number> was removed or the cable to this module was removed. The cable and I/O module were connected to port <port number> of the external controller.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24755
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that either redundant I/O module number <module number> in box <box number> was added or the cable to this module was connected. The cable and I/O module are connected to port <port number> of the external controller.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24756
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that box <box number> connected to port <port number> is now marked as repaired (re-added after a previous failure).
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24757
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that either redundant I/O module number <module number> in box <box number> was repaired or its path was repaired. Box <box number> is connected to port <port number> of the external array controller.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24758
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that redundant path number <path number> for the <drive type> physical drive located in bay <bay number> has either failed or been removed.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24759
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that an unsupported configuration has occurred with the redundant cabling that is attached between port <port number> and box <box number>. <firmware information>. Please check the cabling and ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24760
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that an unsupported configuration has occurred with the redundant cabling that is attached to port <port number>. <firmware information>. Please check the cabling and ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24761
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that an unsupported configuration has occurred with the redundant cabling that is attached to port <port number>. Please check the cabling and ensure that a supported configuration is being used.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24762
Severity: Informational
Log message:
External Smart Array controller number <controller number> located in the MSA chassis labeled as <chassis label> is reporting the following flash operation: "<firmware message>."
The firmware was flashed from:
Revision: <old revision number>
to
Revision: <new revision number>
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24763
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported an uncorrectable read error during rebuild operations for logical drive <logical drive number>. The uncorrectable media defects are between logical block address <lba number 1> and logical block address <lba number 2>. The host will be unable to read some blocks between this address range until the blocks are overwritten. The logical drive rebuild is continuing so that the volume can regain fault tolerance. Capacity expansion operations must be avoided while the affected blocks are unreadable.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24764
Severity: Warning
Log message :The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that the <drive type> physical hard drive located in bay <bay number> is not supported <not supported reason>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
<not supported reason> values:
- “
because it is a singled ported drive
” - “
because it is a SATA drive
” - “
because it is smaller than the drive it is replacing
” - “
because it is of an unrecognized type
” - “
because it contains an unsupported RIS configuration
”
Message Id: 24765
Severity: Informational
Log message: The MSA chassis labeled as <chassis label> has reported that battery pack number <battery pack number> located on controller number <controller number> has been <inserted / removed>.
The external Smart Array controller reporting this operation is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24766
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that the <drive type> physical hard drive located in bay <bay number> is in a SMART predictive failure state.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24767
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that more physical devices were detected than the controller is currently capable of supporting. Some physical drives will not be accessible.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24768
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that the storage enclosure attached to port <port number> with chassis serial number <serial number> has had power supply number <power supply number> <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24769
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that fan number <fan number> located on fan module <fan module number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24770
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that fan number <fan number> located on fan module <fan module number> has failed. The external Smart Array controller may attempt to shut down power and/or spin down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24771
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that fan number <fan number> located on fan module <fan module number> is reporting a degraded condition.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24772
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that fan number <fan number> located on fan module <fan module number> is now operational.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24773
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis number> has reported that a tape drive has been <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24774
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting <link up / down> for PHY number <PHY number>. This PHY link status change has occurred on port <port number> of the external array controller.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.