SymptomHPE OneView displays an error when an
HPE Synergy Frame Link Module and an
HPE Synergy 4-Port Frame Link Module are installed in the same
frame.
CauseDifferent types of frame link modules are installed into the same
frame. The frame link modules in a
frame must be the same type.
Action-
Identify the
frame link module type that should be installed in the
frame.
-
Remove the mismatched
frame link module and disconnect the cables from the
frame link module.
-
Install the matching
frame link module in the empty
frame link module bay.
-
Connect the cables disconnected from the original mismatched
frame link module and connect them to the new
frame link module.
If adding a second
HPE Synergy 4-Port Frame Link Module to the
frame, you need to a transceiver for each CAT 6A cable or DAC cables. If adding a second
HPE Synergy Frame Link Module (2-port) to the
frame, you need to remove the transceivers from each CAT 6A cable or remove DAC cables and replace them with CAT6A cables.