Errors displayed when an HPE Synergy Frame Link Module and an HPE Synergy 4-Port Frame Link Module are installed in the same frame

Symptom

HPE OneView displays an error when an HPE Synergy Frame Link Module and an HPE Synergy 4-Port Frame Link Module are installed in the same frame.

Cause

Different types of frame link modules are installed into the same frame. The frame link modules in a frame must be the same type.

Action
  1. Identify the frame link module type that should be installed in the frame.
  2. Remove the mismatched frame link module and disconnect the cables from the frame link module.
  3. Install the matching frame link module in the empty frame link module bay.
  4. Connect the cables disconnected from the original mismatched frame link module and connect them to the new frame link module.

    If adding a second HPE Synergy 4-Port Frame Link Module to the frame, you need to a transceiver for each CAT 6A cable or DAC cables. If adding a second HPE Synergy Frame Link Module (2-port) to the frame, you need to remove the transceivers from each CAT 6A cable or remove DAC cables and replace them with CAT6A cables.