Frame link module factory reset

IMPORTANT:

When a frame is configured and is actively managed by HPE OneView, a factory reset should only be performed when required by a recommended HPE OneView management or service process.

The Factory Reset action resets all frame link modules in a frame to factory default settings. Resetting a frame link module to factory default settings will take the frame link module offline for up to 10 minutes. If the frame link module is installed in a frame managed by HPE OneView, the frame link module will be reclaimed by HPE OneView after the factory reset is complete.

Some instances where a factory reset may be necessary include:
  • Prior to moving a frame to a new HPE OneView environment.

  • After performing a factory reset of the HPE Synergy Composer that manages the frame.

    For more information, see the HPE OneView for HPE Synergy User Guide on the Hewlett Packard Enterprise Information Library (http://www.hpe.com/info/synergy-docs).