SymptomThe power supply configuration for the
server is insufficient to meet the power requirements for the
server.
CauseThe current power supply configuration is not sufficient to operate the
server.
Action-
Verify that the power supplies support the power requirements for the
server configuration.
-
Verify that all power supplies are supported for this
server.
-
If the power supplies have LEDs, review the LED statuses to see if they indicate an issue:
- If the LEDs display red, replace the power supply.
- If the LEDs display amber, then the power supply is in standby mode.
Press and hold the Power On/Standby button on the server.
- If the LEDs are off, inspect the power source. Then, power on the server again.
- If the power source is working properly, and the LEDs remain off, replace the power supply.
For more information, see the
server maintenance and service guide.
-
Verify that the system has enough power, particularly if you recently added hardware, such as drives.
- To verify that the system has enough power, remove the newly added component.
- If the issue is no longer present, then additional power supplies are required.
- If the issue persists, review the IML for system information.
For more information, see the
server documentation.